External Wall Insulation Open Clad

The system complies with the most stringent of standards – from baseline building regulations through to Passivhaus.

The system is suitable for all open clad finishing options up to and including 30mm gaps.

All components for the system are available from Unity Lime.

CROSS SECTION OF SYSTEM

  1. Open Cladding system
  2. Battened to create a 50mm ventilated void
  3. SOPLUTEC UV Membrane over ISOLAIR (Adhered onto masonry with MC55)
  4. Masonry Substrate
  5. Internal plaster

SYSTEM PERFORMANCE

u-values
0.26 – 0.10

y-values
0.05 – 0.02

Airtightness
5 – 0.6 @50pa